omv6:omv6_plugins:snapraid

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
omv6:omv6_plugins:snapraid [2023/08/03 01:34] – [Prepare for Drive Replacement] crashtestomv6:omv6_plugins:snapraid [2024/04/22 04:02] (current) crashtest
Line 1: Line 1:
-{{indexmenu_n>6}}+{{indexmenu_n>9}}
 \\ \\
 <html><center><b>SnapRAID Plugin For OMV6</b></center></html> <html><center><b>SnapRAID Plugin For OMV6</b></center></html>
Line 375: Line 375:
 When server notifications are -> [[https://wiki.omv-extras.org/doku.php?id=omv6:new_user_guide#server_notifications|configured as recommended]] , user / admins are notified by e-mail of **file system failures** and other issues.\\ When server notifications are -> [[https://wiki.omv-extras.org/doku.php?id=omv6:new_user_guide#server_notifications|configured as recommended]] , user / admins are notified by e-mail of **file system failures** and other issues.\\
 \\ \\
-{{ ::omv6-plugins-snapraid-14.jpg?nolink&600 |}} +{{ ::omv6-plugins-snapraid-14.jpg?nolink&700 |}} 
  
 ---- ----
Line 382: Line 382:
  
 \\ \\
-{{ ::omv6-plugins-snapraid-12.jpg?nolink&800 |}}+{{ ::omv6-plugins-snapraid-12.jpg?nolink&900 |}}
 \\ \\
 ---- ----
 <html><center><b>Physically remove the drive.</b></center></html> <html><center><b>Physically remove the drive.</b></center></html>
-<html><center>If necessary, ref to <b>Storage</b>, <b>Disks</b> and compare serial numbers to the device names under <b>Storage</b>, File <b>Systems</b> to insure the right drive is removed.</center></html>+<html><center>If necessary, refer to <b>Storage</b>, <b>Disks</b> and compare serial numbers to the device names under <b>Storage</b>, File <b>Systems</b> to insure the right drive is removed.</center></html>
 \\ \\
-{{ :omv6-plugins-snapraid-19.jpg?nolink&800 |}}+{{ :omv6-plugins-snapraid-19.jpg?nolink&900 |}}
 ---- ----
  
Line 407: Line 407:
 - Click the **Save** button. - Click the **Save** button.
  
-{{ ::omv6-plugins-snapraid-21.jpg?nolink&600 |}}+{{ ::omv6-plugins-snapraid-21.jpg?nolink&800 |}}
  
 <html><center>When the format is complete, click the <b>Close</b> button.</center></html> <html><center>When the format is complete, click the <b>Close</b> button.</center></html>
Line 415: Line 415:
 \\ \\
  
-{{ ::omv6-plugins-snapraid-22.jpg?nolink&600 |}}+{{ ::omv6-plugins-snapraid-22.jpg?nolink&800 |}}
 \\ \\
 <html><center>Click <b>Save</b> and <b>apply</b> the configuration change.</center></html> <html><center>Click <b>Save</b> and <b>apply</b> the configuration change.</center></html>
Line 424: Line 424:
 <html><center><b>/dev/sde1</b> appears, empty and formatted to <b>EXT4</b></center></html>. <html><center><b>/dev/sde1</b> appears, empty and formatted to <b>EXT4</b></center></html>.
  
-{{ ::omv6-plugins-snapraid-23.jpg?nolink&600 |}}+{{ ::omv6-plugins-snapraid-23.jpg?nolink&800 |}}
  
 ---- ----
Line 470: Line 470:
 {{ ::omv6-plugins-snapraid-26.jpg?nolink&600 |}} {{ ::omv6-plugins-snapraid-26.jpg?nolink&600 |}}
 \\ \\
-<html><center>(The UNRECOVERABLE error may be due to a change made //after// the last **Sync** operation, that cannot be restored.)</center></html> +<html><center>(The UNRECOVERABLE error may be due to a change made <b><i>after</i></b> the last <b>Sync</b> operation, that cannot be restored.)</center></html>  
 ---- ----
  
Line 477: Line 478:
 This concludes data restoration to a SnapRAID protected drive.\\ This concludes data restoration to a SnapRAID protected drive.\\
 **MergerFS users** skip see the section below titled; **Replacing a Failed Drive in MergerFS**. \\   **MergerFS users** skip see the section below titled; **Replacing a Failed Drive in MergerFS**. \\  
 +
 ---- ----
 +
 The remainder of tasks, within OMV, would be to repointing **Shared Folders** and other services to the replacement drive.  To repoint shared folders, see the guidance provided -> [[https://wiki.omv-extras.org/doku.php?id=omv6:utilities_maint_backup#repointing_a_shared_folder|here]].\\ The remainder of tasks, within OMV, would be to repointing **Shared Folders** and other services to the replacement drive.  To repoint shared folders, see the guidance provided -> [[https://wiki.omv-extras.org/doku.php?id=omv6:utilities_maint_backup#repointing_a_shared_folder|here]].\\
 \\ \\
 When all references to the failed drive have been redirected to the new drive, or removed, under **Storage**, **File Systems**, the "**Referenced**" check mark should be removed.  Highlight the **missing** drive, **unmount** it and **Apply** the change.\\ When all references to the failed drive have been redirected to the new drive, or removed, under **Storage**, **File Systems**, the "**Referenced**" check mark should be removed.  Highlight the **missing** drive, **unmount** it and **Apply** the change.\\
 \\ \\
-Finally, re-enable all automated tasks and enable network shared (if previously disabled.)\\+Finally, re-enable all automated tasks and enable SMB or NFS network shares (if previously disabled.)\\
 \\ \\
 \\ \\
  • omv6/omv6_plugins/snapraid.1691026456.txt.gz
  • Last modified: 2023/08/03 01:34
  • by crashtest